A manufacturing plant installs machines from different equipment suppliers over several years. One machine uses an Allen Bradley PanelView interface, another runs Siemens WinCC, while a third uses a Schneider Electric HMI. Each system works as designed, but operators face different screen layouts, alarm messages, navigation methods and operating steps as they move along the same production line.
This creates a problem that is easy to overlook during equipment procurement. Operators must learn several interfaces, maintenance technicians need to search through different menus to find machine faults, and supervisors may struggle to get a clear view of the entire line. The plant does not always need new machines or replacement PLCs to fix this problem. A well planned HMI Programming project can create a consistent operator experience across different original equipment manufacturer (OEM) systems while keeping the existing control equipment in service.
Five machines should not feel like five different operating environments
Imagine a production line with five machines supplied by five different manufacturers. The first machine displays a green indicator when ready, the second uses a text message, and the third places its operating status on a separate screen. An operator who moves between these machines must remember where to find the same basic information and how each supplier presents a fault.
The problem becomes more serious during an equipment stoppage. A maintenance technician may need to open several screens, check different alarm histories and interpret supplier specific terms before identifying which machine has stopped the line. Even when the fault is simple, inconsistent interfaces can add time to diagnosis and make communication between operators and maintenance staff less clear.
The goal of HMI standardization is to make common tasks feel familiar across the production line. Operators should be able to find machine status, active alarms, production information and permitted controls in predictable locations. Each machine can still have its own operating requirements, but the way information is presented should follow a common design approach.
Why this matters to Canadian manufacturers
The availability of experienced production and maintenance staff is a practical concern for Canadian manufacturers. Statistics Canada’s Canadian Survey on Business Conditions for the third quarter of 2026 reported that 38.2% of manufacturing businesses expected difficulty recruiting skilled employees over the following three months. This figure does not measure HMI training needs, but it highlights the value of making plant systems easier for existing and new employees to use.
A consistent interface can help reduce the amount of time operators spend learning different screen structures and locating routine information. It can also make cross training easier when employees need to work at more than one machine or production area. The result depends on the quality of the design and the training provided, but a familiar layout gives the workforce a more consistent starting point.
For a manufacturer running several OEM machines, this is also a maintenance issue. A shared approach to status messages, alarm presentation and navigation can help technicians move between machines without learning an entirely new screen structure at every station.
The real problem is not different brands. It is the lack of a common HMI philosophy.
Different PLC and HMI brands do not automatically create an operating problem. A plant can run Allen Bradley, Siemens, Schneider Electric and Omron equipment on the same production line. Each platform may have its own programming environment and communication requirements, but the plant can still set common rules for how operators interact with the machines.
The difficulty starts when every equipment supplier designs its interface independently. One supplier may use different names for the same machine state, while another may place reset controls in a different menu. Alarm priorities, screen navigation and equipment graphics may also follow unrelated conventions. Over time, the plant ends up managing several interface designs instead of one consistent operating method.
A common HMI philosophy gives the plant a set of design rules for all connected machines. It defines how screens are arranged, how machine states are named, how alarms are presented, which information operators need and how users move between equipment. The rules should support the work performed at the plant rather than force every machine into an identical screen.
For plants formalizing these rules, ISA 101 provides a useful reference for HMI design and management. Its guidance should be considered alongside the plant’s operating procedures, equipment requirements and applicable safety practices.
What should look and behave the same across different HMIs?
Standardization works best when the plant starts with the information and actions that operators use across several machines. The aim is to make common tasks predictable while retaining the controls and details needed for each machine’s specific function.
HMI element | Common design rule | Operational benefit |
Machine status | Use consistent names and clear states such as Running, Stopped, Ready and Faulted | Operators can identify machine conditions faster |
Screen navigation | Keep menu positions and navigation methods consistent | Staff spend less time searching for information |
Alarm messages | Use a common structure for alarm names, priorities and descriptions | Maintenance teams can interpret faults more easily |
Production information | Present key counts, cycle information and output in a consistent layout | Supervisors can review several machines with less confusion |
Colour conventions | Apply an approved plant colour philosophy consistently | Visual indicators carry a clear and predictable meaning |
User access | Apply defined roles and permissions across the system | Operators and maintenance staff receive the access needed for their work |
Equipment graphics | Use consistent symbols and status presentation where appropriate | Similar equipment functions are easier to recognize |
Consistency does not mean that every screen should contain the same buttons or display the same data. A packaging machine, a robot cell and a mixing system perform different tasks, so their detailed operating screens must reflect those differences. The shared rules should cover navigation, status, alarms and presentation, while machine specific screens should retain the controls and process information needed for that equipment.
Build a common screen structure operators can learn once
A useful starting point is to define the information that should appear in the same place on every machine. The plant can then create a standard screen structure that equipment suppliers and HMI programmers use during new installations and upgrades. This gives operators a familiar layout without forcing the engineering team to use one software platform across every controller.
A practical machine screen can use the following structure:
1. Top information area
Display the machine name, production line, selected product, operating mode and communication status. Operators should be able to confirm which machine they are viewing and its current condition without opening another screen.
2. Main process area
Show the key machine information in the largest part of the display. This may include equipment movement, process values, conveyor state, production count or other information required for normal operation.
3. Status and alarm area
Place important equipment conditions and active alarms in a consistent location. Operators should be able to identify the source of a problem and see the information needed to respond.
4. Navigation area
Keep links to machine details, trends, alarm history, production records and maintenance screens in predictable locations. Avoid adding several layers of menus for information that operators need during routine production.
5. User and action area
Display the logged in user and provide access to permitted actions. Controls that start, stop, reset or change a process must follow the approved machine operating procedure and access rules.
This arrangement is a starting point, not a fixed template for every plant. Screen size, viewing distance, equipment function and operator tasks all affect the final layout. The design should be tested with the people who use the machines before the same structure is applied across the full line.
Standardize machine states before redesigning the screens
A common screen layout cannot solve inconsistent machine information on its own. If one PLC reports that a machine is available while another uses a different signal to describe the same condition, the HMI programmer needs to establish how those states should be interpreted and displayed.
Start by reviewing the machine states across all OEM equipment. Identify the conditions that operators need to see, such as Ready, Running, Stopped, Waiting, Faulted, Manual and Maintenance. The plant should then map the available PLC signals to the agreed status definitions without changing the meaning of the original machine logic.
Consider a production line where the first machine displays “Available”, the second uses “Ready for Cycle”, and the third shows “Auto Mode”. These messages do not necessarily describe the same condition. One may indicate that the machine is ready to operate, while another only confirms that automatic mode is selected. The engineering team must confirm the actual signal meaning before applying a common label.
PRO TIP: Build a machine state mapping table before programming the new screens. Record the original PLC tag, its meaning, the common plant status and the conditions required to display that status. This gives operators consistent messages while preserving the information needed for correct machine operation.
Make alarm messages useful across the entire production line
Alarm messages are often one of the biggest differences between OEM interfaces. One machine may show an alarm number, another may use a short text description, and a third may display a technical message that only the original equipment supplier fully understands. During a production interruption, maintenance staff need to identify the affected machine, the reason for the alarm and the appropriate next step.
A common alarm structure should include a clear description, the equipment source, a defined priority and the information needed for diagnosis. Where appropriate, it should also show the time of the event, the current condition and its acknowledgement state. Alarm wording should describe the actual condition rather than use vague messages such as “Machine Error” or “System Fault”.
Inconsistent message | Improved common presentation | Information the operator needs |
Fault 021 | Conveyor motor overload | Equipment name and fault condition |
Sensor error | Part present sensor not detected | Sensor location and expected condition |
System not ready | Downstream machine not ready | Which machine is holding the sequence |
Drive alarm | Motor drive reports a fault | Drive identification and diagnostic reference |
Communication failure | PLC communication unavailable | Affected controller and connection status |
Alarm priorities should follow the plant’s approved alarm philosophy. A fault that requires immediate operator action should not appear with the same priority as a routine status message. Colour should support the message, not carry its meaning alone, because operators also need readable text and clear information about the affected equipment.
Standardization must not remove machine specific diagnostic details. The line may use one common alarm view while retaining the original equipment alarm code and manufacturer reference for technicians who need to investigate the fault. This makes the operator experience simpler without losing technical information.
Can existing PLCs and OEM machines remain in place?
In many cases, yes. HMI standardization does not automatically require a plant to replace its PLCs, machines or control panels. The engineering team can often work with the existing control hardware and develop a more consistent screen design using the programming tools supported by the installed HMI platform.
For example, ControlSoft Canada’s HMI and PLC programming service page lists experience with Allen Bradley CompactLogix and ControlLogix, Schneider Electric Modicon M340 and M580, Siemens SIMATIC controllers and Omron automation controllers. It also identifies HMI platforms such as FactoryTalk Machine Edition with PanelView Plus, Schneider Electric Magelis with Vijeo Designer and Siemens WinCC.
This type of multi platform experience is relevant when a manufacturer needs a common operator design across different OEM machines. The engineering team can review the existing HMI applications, PLC tags, available communication methods and machine functions before deciding how much of the interface needs to change.
There are three practical implementation options:
Option 1: Standardize each existing HMI
Keep the installed HMI hardware and PLCs, then revise the screen layouts, navigation, alarms and common operating information within the supported software platform. This can be a suitable route when the existing hardware remains reliable and has enough capacity for the required changes.
Option 2: Add a common line overview
Retain the local OEM HMIs for detailed machine operation and introduce a line level display for combined status, production information and alarm visibility. This allows supervisors and operators to see the whole line without removing the machine specific interface needed for local tasks.
Option 3: Replace selected HMI applications
Some panels may be obsolete, unsupported or too limited for the required design. In those cases, the plant may decide to replace selected HMI hardware or software while retaining PLCs and other equipment. This option requires a review of communication compatibility, licences, wiring, panel dimensions and the effect on machine operation.
The right choice depends on the condition of the existing systems and the amount of standardization required. A technical assessment should establish what can remain, what needs modification and which changes require PLC programming or additional communication work.
When a common line overview is more useful than five redesigned screens
A line overview gives operators and supervisors a single place to see the condition of several connected machines. It should show which equipment is running, stopped, waiting or faulted, along with the information needed to locate the problem. This is especially useful when a production line has several stations and a fault at one machine can affect equipment further along the process.
The overview should not replace the local HMI for detailed machine operation. Operators may still need the OEM screen to adjust permitted settings, review detailed diagnostics or perform specific machine tasks. The line overview provides a shared picture of production, while the local interface handles the detailed operation of each machine.
Before adding a supervisory screen, confirm which signals are available from the existing PLCs and how frequently the information needs to update. The engineering team should also consider communication failures and stale data. A screen must make it clear when a machine is no longer reporting current information rather than displaying an old status as if it were live.
How to standardize HMI design without disrupting production
A full plant wide redesign can create unnecessary risk when the existing interfaces are still needed for daily operation. A phased rollout gives the team a chance to test the design, gather operator feedback and correct issues before applying the same rules to every machine. It also allows production managers to schedule the work around maintenance periods and planned shutdowns.
A useful rollout can follow this sequence:
Stage 1: Audit the current interfaces
Document all installed HMI panels, software versions, PLC connections, screen structures, alarm messages and operator functions. Identify obsolete hardware, missing backups and interfaces that cannot support the planned changes.
Stage 2: Develop the HMI design rules
Agree on the common screen structure, navigation, status definitions, alarm presentation, colour conventions and user access. Involve operators and maintenance personnel so the design reflects actual plant tasks rather than engineering preference alone.
Stage 3: Select one machine for a pilot
Choose a machine that represents the wider production line but does not create unnecessary production risk. Apply the proposed design, test the common functions and collect feedback from the people who use it during normal operation.
Stage 4: Apply the approved design to other machines
Adapt the standard elements to each OEM platform while retaining the machine specific functions. Keep a record of software versions and approved changes so that the plant can maintain the same design rules during future upgrades.
Stage 5: Train users and review performance
Train operators and maintenance staff on the revised screens, alarm messages and navigation. Review operator feedback, fault response records and training requirements after the rollout to identify areas that need further improvement.
This phased method gives the manufacturer a way to improve the operator experience without taking every machine out of production at the same time. It also provides a controlled process for introducing the standard design to new equipment as the plant expands.
What must be tested before the new HMI design goes live?
A screen can look consistent and still display incorrect information. Testing must confirm that the new interface reads the correct PLC data, displays the actual machine condition and sends only the permitted commands. The engineering team should check both normal operation and fault conditions, with tests carried out under approved site procedures.
Test area | What to verify | Expected result |
Machine status | Running, stopped, ready, waiting and fault states | Each status reflects the actual PLC and equipment condition |
Production data | Counts, cycle information and selected product | Values match the approved source data |
Alarm display | Alarm text, priority, source and acknowledgement | Operators receive clear and accurate fault information |
Navigation | Access to overview, operation and diagnostic screens | Users can find common functions in predictable locations |
User access | Operator, supervisor and maintenance permissions | Users can perform only their approved actions |
Communication | PLC connection loss and recovery | The HMI identifies unavailable or stale information |
Control commands | Permitted start, stop, reset and setting changes | Commands reach the intended equipment and show the actual response |
The test plan should also include a review of machine specific functions that must remain unchanged. Safety related control functions, protective devices and machine interlocks must remain in line with the approved safety design. HMI changes must not bypass or replace the safety systems that protect people and equipment.
Where several OEM machines share information, test the combined line overview as well as the individual screens. Confirm that one machine’s status appears under the correct name, alarms reach the correct location and communication failures do not create misleading line conditions. Record the results, correct any issues and obtain the required approval before releasing the revised HMI design for normal production.
How HMI standardization can reduce training pressure
Training is more difficult when each machine presents information in a different way. A new operator may understand the production process but still need extra time to learn where each supplier has placed its status indicators, alarm history and routine controls. A consistent layout reduces the number of different screen patterns the employee must learn, although machine specific training remains essential.
Maintenance technicians can also benefit from shared navigation and alarm presentation. When the same type of machine condition appears in a predictable place, technicians can spend less time searching through menus and more time checking the actual equipment and control signals. This does not remove the need for knowledge of different PLC platforms, but it makes common diagnostic tasks easier to approach.
Measure the result using practical indicators rather than assuming the redesign has reduced training time. Track how long new operators take to complete defined HMI tasks, how often they request help locating information and how long maintenance staff need to find the source of common alarms. Compare these results before and after the changes, taking account of staff experience and the complexity of the machines.
How ControlSoft Canada supports multi OEM HMI programming
ControlSoft Canada provides HMI and PLC programming services for industrial control systems using multiple controller and interface platforms. Its published service information includes Allen Bradley, Schneider Electric, Siemens and Omron PLC experience, along with HMI development using FactoryTalk, PanelView Plus, Magelis, Vijeo Designer and WinCC. This range is relevant to manufacturers that operate equipment from several OEMs and need a consistent approach to operator interfaces.
For a multi machine production line, the work should begin with an assessment of the existing HMIs and their connections to the PLCs. The engineering team can document screen structures, machine states, alarms, user functions and communication requirements, then identify which elements can follow a shared design. The proposed changes should protect existing machine functions and include a clear plan for testing, operator training and future maintenance.
A manufacturer does not need to start by replacing every panel or controller. In many situations, the more practical first step is to standardize the information operators see and the tasks they perform. ControlSoft Canada can discuss the current control environment and help define an HMI programming scope that fits the installed equipment and production requirements.
Frequently Asked Questions
Can different PLC brands use a standardized HMI design?
Yes. Different PLC brands can support a common HMI design when the required data and control functions are available through compatible communication methods. The engineering team must map each machine’s signals to common plant definitions while preserving its original operating logic. The detailed screens can still use the software platform supported by each installed HMI.
Does HMI standardization require replacing existing PLCs?
No. Many projects can retain the existing PLCs and machines while modifying the HMI applications. The actual scope depends on controller compatibility, available data points, communication access, panel condition and the functions required. A technical assessment should identify the equipment that can remain and any changes needed to support the new interface.
Should every machine have exactly the same HMI screen?
No. Machines perform different tasks and need different operating information. The plant should standardize common elements such as navigation, status presentation, alarm wording, colour conventions and user access, while keeping machine specific process details and controls relevant to each piece of equipment.
How can a manufacturer standardize alarms across several OEM machines?
Start by reviewing the existing alarm lists and confirming what each message represents. Define common naming rules, priorities, descriptions and acknowledgement behaviour, then map the original machine alarms to the agreed plant format. Keep the original diagnostic codes and technical references available for maintenance staff who need detailed troubleshooting information.
Can one central HMI control an entire production line?
A central HMI or supervisory screen can provide a shared view of production status and selected permitted functions across several machines. However, local machine interfaces may still be required for detailed operation, setup and diagnostics. The design should match the plant’s control architecture and must not remove necessary local controls or approved safety functions.
How does HMI programming help reduce operator training requirements?
Consistent screen layouts, navigation, status messages and alarm presentation make common tasks more familiar across different machines. Operators still need machine specific training, but they spend less time learning unrelated interface patterns. Plants can assess the result by tracking task completion, training feedback and operator assistance requests.
What should be checked before implementing a new HMI design?
Review the installed PLCs, HMI software, communication protocols, current tag lists, alarm configurations, user permissions and machine operating requirements. Test normal functions, fault messages, communication loss, control commands and the accuracy of displayed production information. The plant should also approve the design and training plan before the revised interface is released.
One Production Line Should Have One Clear Operating Experience
Different machine brands do not have to create a confusing production environment. A plant can retain its existing OEM equipment and PLCs while applying common rules to screen layouts, navigation, machine status, alarms and operator functions. This gives employees a more consistent way to interact with the production line and gives maintenance teams a clearer starting point when faults occur.
Successful HMI standardization begins with the people who use the machines and the control systems that support them. Review the existing interfaces, define a common HMI philosophy, test the design on a pilot machine and roll out the approved approach in stages. For Canadian manufacturers operating multi OEM production lines, this is a practical way to improve operator consistency without treating equipment replacement as the first solution.